BM11 Load Cell (BM11)
Short Description:
Stainless steel IP68 single ended bending beam
Hermetically sealed
Suitable for pallet, platform and small hopper scales
High accuracy
Current calibrated (SC-option)
Manufacturer: Zemic Europe
Origin: B.V Netherland
Available Models:
Capacity Accuracy Full Article Description 5kg C3 Excluded from OIML BM11-C3-5kg-3B-SC 10kg C3/C4 BM11-C3/C4-10kg-3B-SC 20kg C3/C4 BM11-C3/C4-20kg-3B-SC 30kg C3/C4 BM11-C3/C4-30kg-3B-SC 50kg C3/C4 BM11-C3/C4-50kg-3B-SC 100kg C3/C4 BM11-C3/C4-100kg-3B-SC 200kg C3/C4 BM11-C3/C4-200kg-3B-SC 250kg C3/C4 BM11-C3/C4-250kg-3B-SC 350kg C3/C4 BM11-C3/C4-350kg-3B-SC 500kg C3/C4 BM11-C3/C4-500kg-3B-SC
Technical Specifications of BM11
Accuracy Class C3; OIML R60 C3; OIML R60 C4 Output Sensitivity (FS) mV/V 2.0 ± 0.2 Maximum Capacity (Emax) kg 5,10, 20, 30, 50, 100, 200, 250, 350, 500 Max. Number of Load Cell Intervals nLC 3000; 4000 Ratio of min. LC Verification Interval Y = Emax / Vmin 10000; 15000 Combined Error %FS ≤± 0.020; ≤± 0.0174 Creep Error (30 minutes) %FS ≤± 0.016; ≤± 0.012 Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.015; ≤± 0.010 Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.011; ≤± 0.009 Zero balance %FS ≤± 1.0 Safe overload %FS 150 Ultimate Overload %FS 300 Excitation, Recommended Voltage V 5 ~ 12 Excitation, Maximum Voltage V 18 Input Resistance Ω 460 ± 50 Output Resistance Ω 350 ± 3.5 Insulation Resistance MΩ ≥5000 Compensated Temperature °C -10 ~ 40 Operating Temperature °C -35 ~ 65 Storage Temperature °C -40 ~ 70 Load Cell Weight kg ~0.50 Element Material Stainless Steel Ingress Protection (acc. to EN 60529) IP68 Recommended Torque on Fixation Bolts Nm M8: 25; M10: 50 ATEX Classification (optional) II 1G Ex ia IIC T4 Ga; II 1D Ex ia IIIC T 200 135°C Da; II 3G Ex ic IIC T4 Gc
Wiring:
Cable type: Shielded, 6 and 4 conductor cable , conductor AWG 24
Cable diameter: Ø 5.0mm
Cable length: 4 conductor: 3m, 6 conductor: 6m
Cable jacket: Polyurethane
Shield not connected to element
Wiring Instruction:
For 4 Wire Loadcell: Input (Positive) - Green
Output (Negative) - Red
Input (Negative) - Black
Output (Positive) - WhiteFor 6 Wire Loadcell: Input (Positive) - Green
Sense (Positive) - Yellow
Output (Negative) - Red
Input (Negative) - Black
Sense (Negative) - Blue
Output (Positive) - White
Used in Hopper Scale, Automated servo belt system, PLC Application.
HM9B Loadcell (Analog HM9B)
Short Description:
Nickel-plated alloy steel IP68 dual shear beam
High accuracy
Suitable for trucks, tracks, hoppers and other electronic weighing devices
Current calibrated (sc-option)
Manufacturer: Zemic Europe. (B.V Netherland)
Origin: Assembled in China
Available Capacity:
Capacity Accuracy Full Article Description 10 Ton C3 HM9B-C3-10t-12B-2-FH 20 Ton C3 HM9B-C3-20t-12B-2-FH 25 Ton C3 HM9B-C3-25t-20B(-SC) -2-FH 30 Ton C3 HM9B-C3-30t-20B(-SC) -2-FH 40 Ton C3 HM9B-C3-40t-16B-2-FH 50 Ton C3 HM9B-C3-50t-16B-2-FH
Technical Specifications HM9B
Accuracy Class OIML R60 C3 Output Sensitivity ( FS ) mV/V 2.0 ± 0.002 Maximum Capacity ( Emax ) kg 10, 20, 25 30, 40, 50 Max. Number of Load Cell Intervals nLC 3000 Ratio of min. LC Verification Interval Y = Emax / vmin 15000, 7500 Combined Error %FS ≤± 0.02 Creep Error (30 minutes) %FS ≤± 0.02 Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.02 Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.02 Zero Balance %FS ≤± 1.5 Safe Overload %FS 150 Ultimate Overload %FS 300 Excitation, Recommended Voltage V 5 ~ 12 Excitation, Maximum Voltage V 18 Input Resistance Ω 700 ± 7 Output Resistance Ω 703 ± 4 Insulation Resistance (50V) MΩ ≥5000 Compensated Temperature °C -10 ~ 40 Operating Temperature °C -35 ~ 65 Storage Temperature °C -40 ~ 70 Load Cell Weight kg 10t: 15 20t – 40t: ~17 50t: 25 Element Material Nickel plated alloy steel Ingress Protection (acc. to EN 60529) IP68 Recommended Torque on Fixation Bolts Nm 1100 ATEX Classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G Ex nL IIC T4
Wiring:
Cable type: Shielded, 4 conductor cable, conductor AWG 24
Cable diameter: Ø 5.5mm
Cable length: 16m (standard), 12m & 20m lengths also available
Cable jacket: PVC Shield not connected to the element
Wiring Instruction:
Input(Positive) - Red
Input (Negative) - Black
Output(Positive) - Green
Output(Negative) - White
Shield - Gray
Used in weighing applications for Trucks, vehicles, Transport Vehicles, and heavyweight products-based Scales. It is placed in between the civil structure and the mechanical structure. The weight of a vehicle is measured by a converted signal coming out from its transducer.
HM9B Loadcell (Digital HM9B)
Short Description:
Nickel-plated alloy steel IP68 dual shear beam
High accuracy
Suitable for trucks, tracks, hoppers and other electronic weighing devices
Current calibrated (sc-option)
Manufacturer: Zemic Europe. (B.V Netherland)
Origin: Assembled in China
Available Capacity:
Capacity Accuracy Full Article Description 10 Ton C3 HM9B-C3-10t-12B-2-FH 20 Ton C3 HM9B-C3-20t-12B-2-FH 25 Ton C3 HM9B-C3-25t-20B(-SC) -2-FH 30 Ton C3 HM9B-C3-30t-20B(-SC) -2-FH 40 Ton C3 HM9B-C3-40t-16B-2-FH 50 Ton C3 HM9B-C3-50t-16B-2-FH
Technical Specifications HM9B
Accuracy Class OIML R60 C3 Output Sensitivity ( FS ) mV/V 2.0 ± 0.002 Maximum Capacity ( Emax ) kg 10, 20, 25 30, 40, 50 Max. Number of Load Cell Intervals nLC 3000 Ratio of min. LC Verification Interval Y = Emax / vmin 15000, 7500 Combined Error %FS ≤± 0.02 Creep Error (30 minutes) %FS ≤± 0.02 Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.02 Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.02 Zero Balance %FS ≤± 1.5 Safe Overload %FS 150 Ultimate Overload %FS 300 Excitation, Recommended Voltage V 5 ~ 12 Excitation, Maximum Voltage V 18 Input Resistance Ω 700 ± 7 Output Resistance Ω 703 ± 4 Insulation Resistance (50V) MΩ ≥5000 Compensated Temperature °C -10 ~ 40 Operating Temperature °C -35 ~ 65 Storage Temperature °C -40 ~ 70 Load Cell Weight kg 10t: 15 20t – 40t: ~17 50t: 25 Element Material Nickel plated alloy steel Ingress Protection (acc. to EN 60529) IP68 Recommended Torque on Fixation Bolts Nm 1100 ATEX Classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G Ex nL IIC T4
Wiring:
Cable type: Shielded, 4 conductor cable, conductor AWG 24
Cable diameter: Ø 5.5mm
Cable length: 16m (standard), 12m & 20m lengths also available
Cable jacket: PVC
Shield not connected to the element
Wiring Instruction:
Input(Positive) - Red
Input (Negative) - Black
Output(Positive) - Green
Output(Negative) – White
Shield - Gray
Used in weighing applications for Trucks, vehicles, Transport Vehicles, and heavyweight products-based Scales. It is placed in between the civil structure and the mechanical structure. The weight of a vehicle is measured by a converted signal coming out from its transducer.
B3G Load Cell (B3G)
Short Description:
Stainless steel IP67, “S” type load cell
Tension and compression applications
Suitable for hanging, hopper and other weighing devices
Also available in imperial capacities and dimensions
Manufacturer: Zemic Europe
Origin: B.V Netherland
Available Models:
Capacity Accuracy Full Article Description 50kg C3 B3G-C3-50kg-6B 100kg C3 B3G-C3-100kg-6B 250kg C3 B3G-C3-250kg-6B 500kg C3 B3G-C3-500kg-6B 1ton C3 B3G-C3-1t-6B 2.5ton C3 B3G-C3-2.5t-6B 5ton C3 B3G-C3-5t-6B 7.5ton C3 B3G-C3-7.5t-6B 10ton C3 B3G-C3-10t-6B
Technical Specifications of B3G
Accuracy Class OIML R60 C3 Output Sensitivity ( FS ) mV/V 3.0 ± 0.008 Maximum Capacity ( Emax ) ton 0.05, 0.1 0.25, 0.5, 1, 2.5, 5, 7.5, 10 Max. Number of Load Cell Intervals nLC 3000 Ratio of min. LC Verification Interval Y = Emax / Vmin 7000, 10000, 12000 Combined Error %FS ≤± 0.020 Creep Error (30 minutes) %FS ≤± 0.016 Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.015 Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.011 Zero balance %FS ≤± 1.0 Safe overload %FS 150 Ultimate Overload %FS 300 Maximum Deflection mm 0.1935 ~ 0.4079 Excitation, Recommended Voltage V 5 ~ 12 Excitation, Maximum Voltage V 18 Input Resistance Ω 430 ± 50 Output Resistance Ω 351 ± 2 Insulation Resistance MΩ ≥5000 Compensated Temperature °C -10 ~ 40 Operating Temperature °C -35 ~ 65 Storage Temperature °C -40 ~ 70 Load Cell Weight kg 0.05t – 1t: 0.5-0.8; 2.5t-5t: ~1.5; 7.5t: 3.1; 10t: 5.6 Element Material Stainless Steel Ingress Protection (acc. to EN 60529) IP67 Recommended Torque on Fixation Bolts Nm M8:25; M12:75; M20:450; M24:750; M30:1450 ATEX Classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G Ex nL IIC T4
Wiring:
Cable type: Shielded, 4 conductor cable, conductor AWG 22
Cable diameter: Ø 5.0mm
Cable length: 6m
Cable jacket: Polyurethane
Shield not connected to element
Wiring Instruction:
Input (Positive) - Red
Output (Negative) - White
Input (Negative) - Black
Output (Positive) - Green
Dimension Wise Capacity:
Dimension Capacity L H H1 W1 W M 50-100kg 50.8 60.96 8.89 11.68 15.06 M8 250-500kg 50.8 60.96 8.89 18.03 21.41 M12 1ton 50.8 60.96 8.89 24.38 27.76 M12 2.5ton 76.2 99.06 13.97 24.38 27.76 M20x 1.5 5ton 74.68 99.06 18.37 30.74 34.12 M20 x 1.5 7.5ton 87.38 139.7 27.5 37.08 40.46 M24 x 2 10ton 112.78 177.8 39.9 42.93 46.31 M30 x 2
Used in Single Point Platform, Hanging Scale System, Crane Scale, Automated servo belt system, PLC Application
- 1